modbus_tcp_pi_listen(3)
=======================


NAME
----
modbus_tcp_pi_listen - create and listen a TCP PI Modbus socket (IPv6)


SYNOPSIS
--------
*int modbus_tcp_pi_listen(modbus_t *'ctx', int 'nb_connection');*


DESCRIPTION
-----------
The *modbus_tcp_pi_listen()* function shall create a socket and listen to
maximum _nb_connection_ incoming connections on the specified nodes.  The
context *ctx* must be allocated and initialized with linkmb:modbus_new_tcp_pi[3]
before to set the node to listen, if node is set to NULL, any addresses will be
listen.


RETURN VALUE
------------
The function shall return a new socket if successful. Otherwise it shall return
-1 and set errno.


EXAMPLE
-------

For detailed examples, see source files in tests directory:

- unit-test-server.c, simple but handle only one connection

[source,c]
-------------------
...

ctx = modbus_new_tcp_pi("::0", "502");
s = modbus_tcp_pi_listen(ctx, 1);
modbus_tcp_pi_accept(ctx, &s);

for (;;) {
    rc = modbus_receive(ctx, query);
    modbus_replay(ctx, query, rc, mb_mapping);
}
...

mclose(s);
modbus_free(ctx);
-------------------

- bandwidth-server-many-up.c, handles several connections at once